A safer brick chimney in Rosemead, or less of one if you are going gas
Ask About This Job
Leave a name, a number and a line on your fireplace. Our office calls back to talk it through and set a visit.
The Job, Start to Finish
Old brick chimneys here were mostly laid without steel, and a strong shake can snap one at the roof line. We study the brick and the framing it meets, then lay out the general options: a steel brace from the stack to the roof framing, straps where it passes the floors, or the upper section rebuilt in lighter materials. A home moving to gas often needs far less chimney, which can make that last option the simplest.
Why brick stacks fail in quakes, and where the fuel comes in
Brick and mortar hold up their own weight well and resist sideways shaking poorly. The part of a chimney that rises above the roof has nothing holding its top, so in strong shaking it rocks on its mortar joints, and it tends to break where it leaves the roofline. The pieces land on the roof, punch through it, or fall into the side yard. The San Gabriel Valley knows this well. The 1987 quake, centered in the Whittier Narrows close to this part of the valley, and the 1994 quake both cracked or toppled brick stacks across the county, and plenty of the survivors were patched rather than strengthened. A retrofit is about the chimney you will keep. That is where a gas plan matters. If your next fireplace is a sealed unit with its own short vent, you may not need the old stack at all, and removing it can be both the quake fix and part of the conversion.
In general terms there are four approaches, and many chimneys get a mix. Bracing fixes a steel frame or angle to the upper part of the stack and anchors it into the roof structure below, so the top cannot rock free. Anchoring ties the chimney to the house at the levels where it passes a floor or the ceiling, with steel fastened to the brick on one end and to the joists on the other. A reinforced rebuild takes the upper part down and lays it back up with steel bars and grout in its core, or replaces it above the roof with a lighter framed section around a metal flue. Removal takes the brick off above the roof and closes the opening. Which mix suits a chimney depends on the state of its brick and mortar, how tall it stands, how the house is framed around it, and which fire it will serve.
Matching the retrofit to logs, an insert or a sealed unit
A vented log set uses the original flue, so the chimney has to stay at full height and the retrofit is about holding it there: bracing above the roof, anchors where it passes the framing, and sound mortar under both. An insert also keeps the chimney, but its stainless liner carries the exhaust, so a reinforced rebuild of the upper section does not need new clay tile and can be lighter. A sealed direct-vent fireplace needs no chimney at all. For that choice, taking the brick down above the roof removes the heaviest and most exposed part of the house in one job, and the new fire can sit in the old opening with its pipe run through the wall, or somewhere else in the room. On our published prices a sealed gas unit set into its own spot is $4,600 to $9,250, with the removal and roof work listed on the same quote so the totals can be compared directly.
The visit starts on the roof and in the attic. We look at the brick and mortar above and below the roofline, how the chimney meets the framing, any cracks at the roof joint, and any gap where the stack has pulled away from the wall. Bracing a stack whose mortar has turned soft only puts steel on loose brick, so the findings say plainly when repair or rebuild has to come first. The written quote then sets out each option that fits the house, what it involves, and its price, with no rebate claims and no promises about how any chimney will behave in a future quake. To book, use the contact page and describe the chimney: roughly how tall it stands above the roof, how old the house is, and whether you are keeping wood, moving to an insert or log set, or thinking about a sealed unit.
Four Habits on Every Grimes Chimney Group Visit
Measure First
Opening, flue and gas supply sized before anything is chosen
One Option at a Time
Logs, inserts and wall units laid out side by side
Figures on Paper
Published prices where we have them, a written figure for the rest
Photos Left Behind
Pictures of the finished work go into your report
Where we offer chimney seismic retrofit
Find your city below. Our focus cities carry a dedicated write-up on how this job fits the homes there.
No cities match that search. Try a nearby area name or neighborhood.
Related Work
Chimney Sweep
Tar and soot cleared from a wood flue, whether you keep burning logs or want it ready before a gas conversion.
Learn More →Chimney Inspection
A written read on flue, crown and firebox, done before you choose a gas option or decide to keep burning wood.
Learn More →Chimney Repair
Broken tiles, open joints and a tired crown mended so the flue keeps working, or can take a gas liner later.
Learn More →Fireplace Inspection
An in-room check of firebox, damper, hearth and mantel spacing, aimed at whether gas logs or an insert will fit.
Learn More →Fireplace Repair
Firebrick, refractory panels, dampers and hearths repaired so the opening is sound before a gas set goes in.
Learn More →Chimney Level 2 Inspection
A recorded camera pass up the flue, with attic and roof checks, for a sale, a quake or a planned switch to gas.
Learn More →Chimney Cap Installation
Stainless or copper tops fitted over the flue, chosen to suit a wood fire, an open gas log set or a lined insert.
Learn More →Chimney Flashing Repair
Metal at the roof line around the stack resealed, so winter rain stops reaching the attic and the new gas install.
Learn More →Chimney Masonry Repair
Worn joints, flaking faces and loose courses on brick stacks put right with mortar that suits the old work.
Learn More →Chimney Rebuilds
Stacks past repair taken down and built back, sometimes shorter or lighter when the house is moving to gas.
Learn More →Fireplace Cleaning
Firebox ash, soot on the walls and haze on the doors cleared, with the floor covered while we work.
Learn More →Gas Fireplace Cleaning
Yearly service on gas units: burner, pilot, glass and vent cleared, with a carbon monoxide reading before we leave.
Learn More →Gas Fireplace Repair
Pilots that drop, sparkers that fire with no flame and burners that run weak, tested part by part and fixed.
Learn More →Fireplace Remodel
A new face for the fireplace, often planned together with a gas insert or log set, in stone, tile or plaster.
Learn More →Fireplace Inserts
Gas inserts set into the firebox you have, with a full-height liner, turning an open hearth into a sealed heater.
Learn More →Pellet Stove Repair
A stove that stalls halfway through a hopper, or will not light at all, gets its failed part traced and its exhaust pipe cleared.
Learn More →Wood Stove Repair
Door seals, firebrick, baffles and stovepipe on wood stoves renewed, or the stove weighed against a gas swap.
Learn More →Gas Logs
Ceramic logs on a gas burner placed in the fireplace you already have, with the line, valve and controls run to it.
Learn More →Chimney Crown Repair
Cracked or crumbling chimney tops sealed or poured fresh, so water leaves the stack instead of sinking into it.
Learn More →Dryer Vent Cleaning
Lint cleared from the dryer duct and the outside hood so the machine dries faster and runs cooler.
Learn More →Chimney Liner Installation
Stainless liners run up old masonry flues so a gas insert or a wood stove vents through a sealed pipe.
Learn More →Chimney Leak Repair
Water at the ceiling or inside the firebox traced to its real entry point, then fixed right there.
Learn More →Chimney Waterproofing
A clear treatment brushed onto repaired brick that sheds rain yet lets damp inside the wall dry out.
Learn More →Chimney Damper Repair
Rusted, warped or seized dampers freed, rebuilt or replaced, or swapped for a top-sealing type on the crown.
Learn More →Chimney Chase Cover
Rusted metal lids on prefab chimneys replaced with a stainless cover cut to fit, so water runs off.
Learn More →