Grimes Chimney Group

Find out which gas option your Rosemead chimney can carry

Ask About This Job

The Job, Start to Finish

Choosing between gas logs, an insert or a sealed direct-vent box starts with knowing what the chimney can carry. We look at the firebox, damper, flue tiles, crown and roof joint, then write down what each gas option would ask of this chimney. Level 1 covers the reachable parts. Level 2 adds recorded video of the flue and is the one for a sale or after a quake. NFPA 211 sets the scope.

Firebox, damper and smoke shelf looked over from inside
Crown, cap and roof joint looked at from above
Notes on which gas option this flue can carry
Level 1 for routine use, Level 2 when a sale or quake calls for it
Written findings with photos, to the NFPA 211 scope

Three gas options, three different chimney questions

A log set is the lightest change. It sits in the firebox you already have and sends its exhaust up the flue you already have, so the inspection asks whether that flue is open, sound and drawing. We look for a damper that can be clamped open, for a gas line or a capped stub in the firebox, for soot or debris that would fall onto a burner, and for cracked tile within reach of a light. A chimney that passes those points can usually take a log set with little more than a sweep. One that fails them is not ruled out; it has a list of fixes in front of it, and the report says which ones and in what order. We also say plainly that decorative logs give a handsome flame and modest warmth. If heat is the goal, the findings say which of the other two options the chimney could support.

An insert asks more. It needs a firebox wide and deep enough to hold its steel box, a smoke chamber a liner can pass through, and a top where that liner can finish under a cap. We measure the opening, check whether the damper would have to come out, and look at the crown from the roof, since the liner's top plate rests on it. A sealed direct-vent unit in a new spot asks almost nothing of the old chimney, and sometimes that is the point: if the stack is cracked from top to bottom, the sensible road may be to retire it and put the fire somewhere else. Level 1 costs $56. Nothing is opened up or taken apart at that level. When the switch is firm, or when something inside the flue cannot be judged with a light, a Level 2 with a full video scan at $405 is the better next step.

What the report says and who reads it

The report starts at the hearth and climbs: the brick or metal panels you look at every evening, the damper plate overhead, the flue as far as a light shows, then the crown, the cap and the flashing as seen from the roof. Each finding carries one of three labels written for a household that is thinking about gas: ready for gas as it is, ready once a named repair is done, or not worth repairing for gas use. Owners use the report in different ways. Some keep burning wood and want the yearly check. Some are about to price a conversion and want to know which quotes are worth asking for. Some are selling a house in Rosemead or Temple City and want the fireplace described honestly before a buyer's inspector gets to it. The same findings serve all three, and the wording stays plain so you can forward it without a glossary.

To book, use the contact page and give the address, what the fireplace burns today and which gas option you lean toward, if any. Larger houses with a second fireplace in a den or a main bedroom are inspected one hearth at a time, each at the same Level 1 price. We do not sell a gas unit on the inspection visit. If the findings point toward an insert or a log set, the report explains why, and any price comes later on a separate written quote you are free to compare with anyone else's. If the chimney turns out to need repair before any gas appliance should use it, that repair is listed with the reason and a rough order of urgency. Sellers and buyers working to an escrow schedule have their own page, which explains how the report fits a sale.

Four Habits on Every Grimes Chimney Group Visit

Measure First

Opening, flue and gas supply sized before anything is chosen

One Option at a Time

Logs, inserts and wall units laid out side by side

Figures on Paper

Published prices where we have them, a written figure for the rest

Photos Left Behind

Pictures of the finished work go into your report

Related Work

Chimney Sweep

Tar and soot cleared from a wood flue, whether you keep burning logs or want it ready before a gas conversion.

Learn More →

Chimney Repair

Broken tiles, open joints and a tired crown mended so the flue keeps working, or can take a gas liner later.

Learn More →

Fireplace Inspection

An in-room check of firebox, damper, hearth and mantel spacing, aimed at whether gas logs or an insert will fit.

Learn More →

Fireplace Repair

Firebrick, refractory panels, dampers and hearths repaired so the opening is sound before a gas set goes in.

Learn More →

Chimney Level 2 Inspection

A recorded camera pass up the flue, with attic and roof checks, for a sale, a quake or a planned switch to gas.

Learn More →

Chimney Cap Installation

Stainless or copper tops fitted over the flue, chosen to suit a wood fire, an open gas log set or a lined insert.

Learn More →

Chimney Flashing Repair

Metal at the roof line around the stack resealed, so winter rain stops reaching the attic and the new gas install.

Learn More →

Chimney Masonry Repair

Worn joints, flaking faces and loose courses on brick stacks put right with mortar that suits the old work.

Learn More →

Chimney Rebuilds

Stacks past repair taken down and built back, sometimes shorter or lighter when the house is moving to gas.

Learn More →

Fireplace Cleaning

Firebox ash, soot on the walls and haze on the doors cleared, with the floor covered while we work.

Learn More →

Gas Fireplace Cleaning

Yearly service on gas units: burner, pilot, glass and vent cleared, with a carbon monoxide reading before we leave.

Learn More →

Gas Fireplace Repair

Pilots that drop, sparkers that fire with no flame and burners that run weak, tested part by part and fixed.

Learn More →

Fireplace Remodel

A new face for the fireplace, often planned together with a gas insert or log set, in stone, tile or plaster.

Learn More →

Fireplace Inserts

Gas inserts set into the firebox you have, with a full-height liner, turning an open hearth into a sealed heater.

Learn More →

Pellet Stove Repair

A stove that stalls halfway through a hopper, or will not light at all, gets its failed part traced and its exhaust pipe cleared.

Learn More →

Wood Stove Repair

Door seals, firebrick, baffles and stovepipe on wood stoves renewed, or the stove weighed against a gas swap.

Learn More →

Gas Logs

Ceramic logs on a gas burner placed in the fireplace you already have, with the line, valve and controls run to it.

Learn More →

Chimney Seismic Retrofit

Old brick stacks braced, strapped or cut down and built back lighter, often planned alongside a move to gas.

Learn More →

Chimney Crown Repair

Cracked or crumbling chimney tops sealed or poured fresh, so water leaves the stack instead of sinking into it.

Learn More →

Dryer Vent Cleaning

Lint cleared from the dryer duct and the outside hood so the machine dries faster and runs cooler.

Learn More →

Chimney Liner Installation

Stainless liners run up old masonry flues so a gas insert or a wood stove vents through a sealed pipe.

Learn More →

Chimney Leak Repair

Water at the ceiling or inside the firebox traced to its real entry point, then fixed right there.

Learn More →

Chimney Waterproofing

A clear treatment brushed onto repaired brick that sheds rain yet lets damp inside the wall dry out.

Learn More →

Chimney Damper Repair

Rusted, warped or seized dampers freed, rebuilt or replaced, or swapped for a top-sealing type on the crown.

Learn More →

Chimney Chase Cover

Rusted metal lids on prefab chimneys replaced with a stainless cover cut to fit, so water runs off.

Learn More →
Book a Visit