Swapping wood for gas is a change of appliance, and the chimney gets a vote. Before Grimes Chimney Group sets an insert or a log set into a Rosemead fireplace, someone has looked properly at the flue the gas is going to use. This post explains which inspection that is, what it costs, what it tends to turn up and how its findings change the conversion quote.

Why the flue matters more after the switch

Wood smoke is hot and fairly dry. It climbs fast and leaves soot and tar on the way. Gas exhaust runs cooler and carries a lot of water vapor. In a tall, wide masonry flue built for wood, that vapor can cool and turn to water on the tile before it reaches the top. Over the years that moisture works on the mortar joints, the tile and the crown.

That is one reason a sealed insert runs its own pipes to the top instead of breathing through the open flue. It is also why a log set, which does use the open flue, needs that flue in good order. A crack that let a wisp of smoke through during a handful of wood fires can let exhaust into the wall cavity every evening the gas is on.

Which inspection

NFPA 211, the fire code document most chimney inspectors work from, describes three depths of inspection. The middle depth, Level 2, is the one it points to when an appliance is replaced by a different kind or when a fireplace changes fuel. Going from wood to gas is both at once.

A Level 2 at our published rate is $405. What separates it from the basic look ($56) is that a camera climbs the whole flue and records the inside, and we look at the chimney in the attic and from the roof as well as from the firebox. The basic look sees the first few feet of flue from below and the top from above; the camera sees the long middle stretch nobody else can.

The deepest level means opening walls or masonry, and it only comes up when the first two point to something hidden.

What the camera tends to find

In older Rosemead chimneys, the findings that change a gas quote fall into a short list.

  • Cracked or offset flue tiles, often halfway up where no flashlight reaches.
  • Open mortar joints between tiles.
  • Old creosote, which has to come out before any pipe goes in.
  • A damper that has rusted solid, or one that sits in the path an insert's pipes need.
  • A crown or cap that lets water in at the top.

Each finding is recorded with where it sits in the flue and what it means for the option you are considering. A cracked tile matters a great deal for a log set and much less for an insert whose pipes run past it.

How the findings reshape the quote

The report feeds straight into the conversion price. A sound flue keeps every option open at its normal figure. A damaged one shifts things.

For a log set, the flue needs repair or a liner first. Our post on pricing a liner for a gas conversion covers that cost.

For an insert, the pipes usually take care of the flue, but the top of the chimney still has to give them a sound place to end. A crown or cap problem gets its own line.

For a new sealed unit in another room, the old chimney drops out of the venting path, and the findings only matter if you plan to keep using the old fireplace.

Where the camera turns up something that rules an option out, the report says so in plain words, and the quote that follows is built around it.

What decides the next step

Three things: the age of the chimney, whether it has had a leak or a crack noted before, and which gas option you are leaning toward. A younger chimney with a quiet history heading for an insert may need less than an older one heading for a log set. When you book, we say which inspection we recommend and why.

To book it, use the quote form and tell us which gas option you are leaning toward and roughly when wood was last burned. We reply with the inspection we recommend and a day for it.

Sweep first, if wood was burned

A camera cannot see through soot. If the fireplace has burned wood in recent winters, a sweep (from $435) goes ahead of the inspection, usually on the same visit. That also leaves the flue ready for whatever goes into it next.

What the report holds

The report goes to whoever booked the visit. It carries still frames from the camera, where in the flue each finding sits and a recommendation for each one, written for a homeowner rather than for another inspector. If you are buying a house in Rosemead and plan to convert after closing, our home sale inspection page explains how the same Level 2 fits inside a purchase.

After the inspection

With the report in hand, you can choose among the three gas options knowing what the chimney will need for each. Our post on gas logs, an insert or direct vent lays those out, and what a gas insert costs prices the most common one.

When you want the flue looked at, the contact page is the place to begin. Mention the gas option on your mind and we plan the visit around it.

Ready to Price It for Your Fireplace?

Grimes measures the opening, looks up the flue and lays out logs, an insert or a wall unit on paper, each with its figure. Visits run from Rosemead to Temple City, Baldwin Park, Los Angeles and the other cities on our area pages.